Custom manufacturing support for product teams worldwide Discuss Your Project  →

Plastic Connector Housings and Insulators

Part types / Plastic Connector Housings and Insulators

Connector housings, terminal blocks, stand-offs and insulating parts are the plastic that holds contacts, isolates a conductor or spaces a board. They are typically small, dimensionally tight around the contact, and often need a heat- or flame-related grade that you specify. This page covers that part type: materials and processes usually reviewed, design points, and what to send. It is not a connector catalog and it does not sell contacts or finished connectors as SKUs. Market context sits on electronics and in the electronics and automotive tables on applications. We go through it with the factory that suits the part. No UL, IEC or similar certification is claimed here; if you need a rated grade, name the rating and the thickness, and the factory confirms what they can offer.

Generic illustration of unbranded plastic electronic housings and insulator parts

Parts in this group

Part What is usually important
Connector and header housingsCavity size, contact retention, mating face, polarization, flammability if you require it
Terminal blocks and fuse holdersPitch, creepage and clearance as you specify, heat from the conductor
Stand-offs, spacers and insulatorsHeight, hole size, dielectric need, stiffness
Coil formers and bobbinsTemperature, winding access, dimensional stability
Sensor or module shells with contactsCombined housing and connector features; see also enclosures

Materials usually reviewed

Material Where typically used Notes
PBTMany connector housingsDimensional stability, electrical properties, common in glass-filled and flame-rated grades when those grades are specified.
Nylon (often glass-filled or a specified FR grade)Housings, blocks, some harsh environmentsTough; moisture moves dimensions. See glass-filled nylon.
PPSHigher temperature, some under-hood or high-heat electronicsUsed when the duty needs it.
PEI, PC or othersWhen you specify heat, clarity or a particular electrical needGrade selection follows the requirement, not a generic “electrical plastic” label.
Thermosets such as G10/FR4 or epoxyMachined insulators, fixtures, some high-temperature blocksOften machined from laminate or cast, not injection molded.

Send your connector housing for review

Process choice

Process When it is typically reviewed
Injection moldingThe usual route for housings and blocks at volume, including fine cavities
Insert moldingContacts, nuts or shields molded in. See also insert vs overmolding.
CNC machiningStand-offs, insulators and low-volume blocks from stock, including laminates
Prototype tooling or vacuum castingEarly fit of a housing before a hard tool, with the limit that electrical and heat behavior may not match the production grade

Design points

  • Freeze the contact or terminal drawing first. The plastic cavity is built around it, not the other way around.
  • State pitch, retention feature, mating face and any polarization so the tool side actions can be planned.
  • If a flame rating is required, name the standard, the color and the wall thickness it applies to. A thin wall may not carry the same rating as a data-sheet plaque.
  • Allow for glass-filled shrink and for nylon moisture on fine cavities.
  • Put gates and ejectors where they will not sit on a sealing or a mating face.
  • If contacts are stitched or inserted after molding, leave lead-in and support, and say who installs them.
  • Creepage, clearance and comparative tracking, if you use them, are your design rules to state; they are not implied by this page.

Ratings, documents and honesty

Flame, glow-wire, automotive or similar documents belong to a tested grade in a tested construction. We won’t make up a certification or print a mark you didn’t ask for and the factory can’t back up. If your customer requires a listed compound, send the requirement and, where you have it, the preferred grade. The review then confirms availability, color and thickness, or explains the gap. The same applies to medical or aviation programs: use the medical-device-style housings and aviation pages for context, and do not treat a connector housing on this site as a qualified device or a certified aircraft part.

Assembly and inspection

Contact retention, cavity size and mating force should be in the inspection plan when the housing is meant to hold a terminal. A first-article pack may include a sectioned cavity, a go/no-go pin and a photograph of the mating face. If ProteForm is also asked to install contacts or to ship a kit, that work is finished assembly and should be in the same RFQ. See sample approval and FAI.

Routes compared

Route Strengths Limits
Molded housingFine cavities at volume, consistent mating facesTooling; late contact changes are expensive
Insert-molded contactsOne part, contacts already placedTooling complexity; repair of a bent contact is harder
Machined insulatorNo mold, many stock materialsNot suited to fine multi-cavity connectors

What to include in an RFQ

  • CAD of the housing and of the contact or terminal it holds.
  • Any flame, heat or documentation requirement, named as a standard and a thickness or a preferred grade.
  • Environment: temperature, fluids, UV, mating cycles.
  • Whether contacts are supplied, inserted or left out, and the quantity.

See also enclosures, brackets and clips and the part-types catalog.

Color, opacity and mold deposits

Most housings in this group are opaque and a defined color, often natural, black or a customer color. Translucent or laser-markable grades, if you need them, should be named early because they are not always a drop-in for a standard FR compound. Some flame-retardant systems are more abrasive or more prone to corrosion in the tool; that’s mainly the factory’s process call, but it can affect lead time and tool steel, so it belongs in the review rather than as a surprise at T1. See mold steel selection when a long-running, filled FR grade is likely.

Low volume and redesign

If the contact is still changing, do not cut a multi-cavity housing tool around it. Machined fixtures and a soft tool, or even a printed housing for mechanical fit only, will tell you more at lower cost. Once the interface is frozen, a well-specified single-cavity tool is the usual first production step. Replacement housings from a broken sample are possible; matching a discontinued rated grade may not be, if that compound has been withdrawn, so send any grade name you still have. See replacement plastic parts.

When the same housing is used with two contact lengths or two keying features, a shared cavity with inserts is sometimes practical. Say that in the RFQ rather than assuming a family tool will be offered; the contact layout has to allow it, and the first review is the time to check.

Frequently asked questions

What plastic is typically used for a connector housing?

PBT and nylon, often in glass-filled or specified flame-rated grades, are common starting points. PPS, PEI and others are reviewed when heat or a particular duty leads. Our PBT vs nylon for electrical housings guide covers how moisture and latch design change that choice.

Can contacts be insert-molded?

Yes. Insert molding is often reviewed when terminals, nuts or shields are part of the housing. The contact drawing should be in the first review.

Will the part be UL listed?

Only if you specify a rating and a grade that can be shown to support it. This page does not claim a certification.

Do you sell finished connectors from stock?

No. We get custom housings and insulators made. We don’t sell catalog connectors.

Can an insulator be machined instead of molded?

Yes, especially stand-offs, spacers and low-volume blocks, including thermoset laminates.

Send your connector housing for review

Send us your drawing

A real engineer reads every request and comes back with questions or a plan for quoting.

ProteForm short RFQ

Or message us on WhatsApp.

Send Drawings
Chat on WhatsApp