Custom manufacturing support for product teams worldwide Discuss Your Project  →

G10 / FR4 Machined Parts: Insulators, Spacers and Fixtures

Materials / Thermosets / G10 / FR4

G10 and FR4 are the materials machinists reach for when a part must be stiff, strong, flat and electrically insulating all at once: insulators, spacers, standoffs, test fixtures, washers and brackets. They are glass-fabric epoxy laminates, so they behave more like a composite than a plastic. They are also abrasive to machine, make hazardous dust, and can delaminate at edges if cut carelessly. This page covers how to specify G10 and FR4 machined parts.

Dark mineral-filled thermoset housings and a light insulator block on a cool gray surface

What G10 and FR4 are and where they fit

G10 is a laminate of woven glass fabric in an epoxy resin, cured under heat and pressure into sheet, rod and tube. FR4 is the flame-retardant version and is the same base material used for printed circuit boards. In practice, many suppliers sell FR4 where G10 is asked for. Because they are cured thermosets, they don’t melt; parts are made by machining the laminate.

They sit on the thermosets page with epoxy, phenolic and BMC/SMC. Compared with unfilled plastics such as acetal, they are much stiffer and stronger, but they are abrasive and not suited to sliding wear in the same way.

Properties you can plan around

G10 and FR4 offer high strength and stiffness for a non-metal, excellent electrical insulation, low moisture absorption, good dimensional stability across temperature, and flatness in sheet form. FR4 adds flame resistance. They resist many chemicals and keep their properties at temperatures where many thermoplastics soften.

The limits are machining and direction. The laminate is anisotropic: strength and expansion differ in the plane of the fabric and through the thickness, and it can delaminate if loaded through the thickness or drilled carelessly near an edge. Glass makes it very abrasive, and machining produces fine glass and resin dust that needs proper extraction. Sheet thickness tolerances can be wider than machined tolerances. Exact properties depend on the grade and supplier.

If your part needs… G10 / FR4 is usually… Talk to us about…
Electrical insulation with high strengthA strong candidate.Required electrical values and test method.
Flame resistanceFR4.The rating and documents for the specific grade.
Stiff, flat fixturesA good candidate.Sheet thickness tolerance and flatness.
Sliding wear against metalNot ideal.Acetal, nylon or PTFE-filled materials.
Molded shapesNot possible as laminate.Machining, or BMC/epoxy molding compounds.
Loads through the thicknessCheck carefully.Orientation, edge distance and delamination risk.

Send drawings for a G10 / FR4 parts quote

Typical applications for G10 / FR4

These are places where G10 / FR4 is typically used and why. They are general examples, not projects or customers of ProteForm. Images are generic illustrations.

Generic illustration of dark thermoset housings and a light insulator block

Electrical insulators, spacers and standoffs

Why this material: High dielectric strength with high mechanical strength.

Usual process: CNC machining

Generic illustration of unbranded plastic electronic housings and insulator parts

Test fixtures and jigs for electronics

Why this material: Stiff, flat and dimensionally stable, and it does not conduct.

Usual process: CNC machining

Washers, bushings and wear plates

Why this material: Strength and low moisture absorption.

Usual process: CNC machining

Generic illustration of equipment housings and guards

Structural brackets in equipment

Why this material: High strength-to-weight compared with unfilled plastics.

Usual process: CNC machining

Processes we can coordinate for G10 / FR4

CNC machining of sheet, rod and tube is the standard route. It needs carbide or diamond tooling, controlled feeds to avoid edge chipping and delamination, and dust extraction. Holes near edges and thin webs need care. Waterjet cutting is used for some flat profiles, and edges can be sealed when moisture or dust matters.

G10 and FR4 can’t be injection molded. If you need a molded insulating thermoset shape at volume, epoxy, phenolic or BMC molding compounds are reviewed instead.

Design and tolerance notes for G10 / FR4

  • Orient parts so main loads run in the plane of the fabric, not through the thickness.
  • Keep holes and slots a sensible distance from edges to avoid breakout and delamination.
  • Use the nearest standard sheet thickness where you can, and tolerance thickness separately if it is critical.
  • Avoid fine tapped threads that can strip; use inserts or through-bolts for repeated assembly.
  • State any electrical test, such as dielectric strength, and the test condition.
  • Specify edge sealing or finishing if exposed edges matter.

Common grades and forms

G10 and FR4 sheet in many thicknesses is standard, along with rod and tube. G11 and similar grades are made for higher temperatures. Other laminates, such as cotton or paper phenolic and glass-silicone, are used for different electrical or machining needs. Color is usually natural green or yellow, with black available. Documentation applies to specific grades and suppliers.

G10 / FR4 compared with acetal and PEI

Question G10 / FR4 Acetal (POM) PEI
Stiffness and strengthVery highModerateHigh
Electrical insulationExcellentGoodVery good
Heat resistanceHighModerateHigh
MachiningAbrasive, dust control neededExcellentGood
MoldableNo (laminate)YesYes
Sliding wearPoor (abrasive)Very goodModerate

For moving or sliding parts, compare with acetal. For insulating parts that need to be molded or machined to more complex shapes, compare with PEI.

What to put in your G10 / FR4 RFQ

  • 2D drawing or 3D CAD with critical dimensions and thickness tolerance.
  • G10, FR4 or another laminate grade, and color.
  • Electrical, flame or temperature requirements and documents.
  • Load direction and fastening method.
  • Edge finish or sealing needs.
  • Quantities and sheet sizes.

Frequently asked questions

What is the difference between G10 and FR4?

Both are glass-fabric epoxy laminates. FR4 is the flame-retardant version. Many suppliers supply FR4 when G10 is requested; if flame resistance is not wanted or a specific grade is required, say so.

Can G10 be injection molded?

No. G10 is a cured laminate, so parts are machined from sheet, rod or tube. Molded insulating thermoset parts use molding compounds instead.

Why is machining G10 more expensive than plastics like acetal?

The glass fibers wear tools quickly, the dust needs extraction, and edges must be cut carefully to avoid chipping and delamination.

Is G10 a good electrical insulator?

Yes. It is widely used for insulators, spacers and fixtures. Required electrical values should be specified with a test condition and confirmed on the grade.

Can G10 replace aluminum in a bracket?

Sometimes, where insulation, weight or corrosion matter. It is less stiff than aluminum and behaves differently through its thickness, so loads and orientation must be checked.

Send drawings for a G10 / FR4 parts quote

Send us your drawing

A real engineer reads every request and comes back with questions or a plan for quoting.

ProteForm short RFQ

Or message us on WhatsApp.

Send Drawings
Chat on WhatsApp