Connector housings, terminal blocks, stand-offs and insulating parts are the plastic that holds contacts, isolates a conductor or spaces a board. They are typically small, dimensionally tight around the contact, and often need a heat- or flame-related grade that you specify. This page covers that part type: materials and processes usually reviewed, design points, and what to send. It is not a connector catalog and it does not sell contacts or finished connectors as SKUs. Market context sits on electronics and in the electronics and automotive tables on applications. We go through it with the factory that suits the part. No UL, IEC or similar certification is claimed here; if you need a rated grade, name the rating and the thickness, and the factory confirms what they can offer.
Parts in this group
| Part | What is usually important |
|---|---|
| Connector and header housings | Cavity size, contact retention, mating face, polarization, flammability if you require it |
| Terminal blocks and fuse holders | Pitch, creepage and clearance as you specify, heat from the conductor |
| Stand-offs, spacers and insulators | Height, hole size, dielectric need, stiffness |
| Coil formers and bobbins | Temperature, winding access, dimensional stability |
| Sensor or module shells with contacts | Combined housing and connector features; see also enclosures |
Materials usually reviewed
| Material | Where typically used | Notes |
|---|---|---|
| PBT | Many connector housings | Dimensional stability, electrical properties, common in glass-filled and flame-rated grades when those grades are specified. |
| Nylon (often glass-filled or a specified FR grade) | Housings, blocks, some harsh environments | Tough; moisture moves dimensions. See glass-filled nylon. |
| PPS | Higher temperature, some under-hood or high-heat electronics | Used when the duty needs it. |
| PEI, PC or others | When you specify heat, clarity or a particular electrical need | Grade selection follows the requirement, not a generic “electrical plastic” label. |
| Thermosets such as G10/FR4 or epoxy | Machined insulators, fixtures, some high-temperature blocks | Often machined from laminate or cast, not injection molded. |
Send your connector housing for review
Process choice
| Process | When it is typically reviewed |
|---|---|
| Injection molding | The usual route for housings and blocks at volume, including fine cavities |
| Insert molding | Contacts, nuts or shields molded in. See also insert vs overmolding. |
| CNC machining | Stand-offs, insulators and low-volume blocks from stock, including laminates |
| Prototype tooling or vacuum casting | Early fit of a housing before a hard tool, with the limit that electrical and heat behavior may not match the production grade |
Design points
- Freeze the contact or terminal drawing first. The plastic cavity is built around it, not the other way around.
- State pitch, retention feature, mating face and any polarization so the tool side actions can be planned.
- If a flame rating is required, name the standard, the color and the wall thickness it applies to. A thin wall may not carry the same rating as a data-sheet plaque.
- Allow for glass-filled shrink and for nylon moisture on fine cavities.
- Put gates and ejectors where they will not sit on a sealing or a mating face.
- If contacts are stitched or inserted after molding, leave lead-in and support, and say who installs them.
- Creepage, clearance and comparative tracking, if you use them, are your design rules to state; they are not implied by this page.
Ratings, documents and honesty
Flame, glow-wire, automotive or similar documents belong to a tested grade in a tested construction. We won’t make up a certification or print a mark you didn’t ask for and the factory can’t back up. If your customer requires a listed compound, send the requirement and, where you have it, the preferred grade. The review then confirms availability, color and thickness, or explains the gap. The same applies to medical or aviation programs: use the medical-device-style housings and aviation pages for context, and do not treat a connector housing on this site as a qualified device or a certified aircraft part.
Assembly and inspection
Contact retention, cavity size and mating force should be in the inspection plan when the housing is meant to hold a terminal. A first-article pack may include a sectioned cavity, a go/no-go pin and a photograph of the mating face. If ProteForm is also asked to install contacts or to ship a kit, that work is finished assembly and should be in the same RFQ. See sample approval and FAI.
Routes compared
| Route | Strengths | Limits |
|---|---|---|
| Molded housing | Fine cavities at volume, consistent mating faces | Tooling; late contact changes are expensive |
| Insert-molded contacts | One part, contacts already placed | Tooling complexity; repair of a bent contact is harder |
| Machined insulator | No mold, many stock materials | Not suited to fine multi-cavity connectors |
What to include in an RFQ
- CAD of the housing and of the contact or terminal it holds.
- Any flame, heat or documentation requirement, named as a standard and a thickness or a preferred grade.
- Environment: temperature, fluids, UV, mating cycles.
- Whether contacts are supplied, inserted or left out, and the quantity.
See also enclosures, brackets and clips and the part-types catalog.
Color, opacity and mold deposits
Most housings in this group are opaque and a defined color, often natural, black or a customer color. Translucent or laser-markable grades, if you need them, should be named early because they are not always a drop-in for a standard FR compound. Some flame-retardant systems are more abrasive or more prone to corrosion in the tool; that’s mainly the factory’s process call, but it can affect lead time and tool steel, so it belongs in the review rather than as a surprise at T1. See mold steel selection when a long-running, filled FR grade is likely.
Low volume and redesign
If the contact is still changing, do not cut a multi-cavity housing tool around it. Machined fixtures and a soft tool, or even a printed housing for mechanical fit only, will tell you more at lower cost. Once the interface is frozen, a well-specified single-cavity tool is the usual first production step. Replacement housings from a broken sample are possible; matching a discontinued rated grade may not be, if that compound has been withdrawn, so send any grade name you still have. See replacement plastic parts.
When the same housing is used with two contact lengths or two keying features, a shared cavity with inserts is sometimes practical. Say that in the RFQ rather than assuming a family tool will be offered; the contact layout has to allow it, and the first review is the time to check.
Frequently asked questions
What plastic is typically used for a connector housing?
PBT and nylon, often in glass-filled or specified flame-rated grades, are common starting points. PPS, PEI and others are reviewed when heat or a particular duty leads. Our PBT vs nylon for electrical housings guide covers how moisture and latch design change that choice.
Can contacts be insert-molded?
Yes. Insert molding is often reviewed when terminals, nuts or shields are part of the housing. The contact drawing should be in the first review.
Will the part be UL listed?
Only if you specify a rating and a grade that can be shown to support it. This page does not claim a certification.
Do you sell finished connectors from stock?
No. We get custom housings and insulators made. We don’t sell catalog connectors.
Can an insulator be machined instead of molded?
Yes, especially stand-offs, spacers and low-volume blocks, including thermoset laminates.